Water Demand Managing System (WDMS)

APPLICATION

Measures the volume of cold potable water. May be used for domestic and small business applications

FEATURES

Fully sealed housing with pop up lid. Easy leak detection in one piece moulded housing
Mud and roots contamination free
Repair and replacement of all components In-situ, using unique non-standard tools
Fundamental product that is easily upgraded from basic management (no meter) to 15mm or 20mm meter with/without flow regulating device
Upgradeable to automatic meter reading as and when required
Pressure independent with IFRD flow regulating device
Pressure management with IFRD flow regulating device
Dual housing available offer cost savings in product and installation

Nominal Bore * Flow Rate * Pressure * Installation * Class
Meter performance Qp 1,5m³/h 2,5m³/h
Nominal bore mm 15 20
Maximum flow rate Qs +/-2% m³/h 3,0 5,0
Permissible flow rate Qp +/-2% m³/h 1,5 2,5
Transitional flow rate Qt +/-2% 1/h 120 37,5
Minimum flow rate Qmin +/-5% 1/h 30 25
Max head loss kPa 60 60
Pressure rating - factory tested kPa 2400 kPa 1600 1600
Max water temperature 30 30
Installation Horizontal Horizontal
SABS No 1428 1428
Meteorological class* B* C*

Meter unit & Workstation Diagram

DIMENSIONS Mono Box Dual Box
Box Height mm 334 334
Box Diameter mm 284 284 x 400
Total Mass grams 2220 3775
End Connectors - Female inches 3/4” BSP 3/4” BSP
Installation Depth mm 300 300
Compression Fittings - HDPE mm 20/25 20/25